Catálogo General de Material para Laboratorio
976 Polarimeters 1 Article Order No. 1 Polarimeter P3000 10 61 13000 2 Digital polarimeter P8000 series The polarimeters of the P8000 series are the fastest polarimeters in the world – thanks to the patented measuring method, which reduces the measuring time to approx. 1 s regard- less of the sample’s angle of rotation. The P8000 instruments measure up to an optical density of 3.0 OD. They are used when particularly high demands are placed on measure- ment accuracy and on continuous data recording and data backup. The instruments have all the functions required in FDA-regulated areas and meet all requirements of GMP/GLP and international standards. Technical data: Scales: Optical rotation [°] Int. sugar scale [°Z] Concentration [g/100 ml] Spec. rotation User-defined Measurement range: ±90° ±259°Z Measurement accuracy: 0.001° 0.01°Z ml Measurement period ± 90°: approx. 1 s Light source: 1 LED with filter Wavelength: 589 nm Temperature measurement range: 0 – 99.9°C Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±0.2°C Type Measurement accuracy Equipment Order No. P8000 ±0.003° ±0.01°Z Without temperature control 63 61 80000 P8100 ±0.002° ±0.01°Z Without temperature control 10 61 18102 2 P8000-T ±0.003° ±0.01°Z With circulation thermostat tem- perature control 10 61 18002 P8100-T ±0.002° ±0.01°Z With circulation thermostat tem- perature control 10 61 18103 P8000-TF ±0.003° ±0.01°Z With circulation thermostat tem- perature control 10 61 18003 P8100-TF ±0.002° ±0.01°Z With circulation thermostat tem- perature control 10 61 18104 P8000-P ±0.003° ±0.01°Z With Peltier temperature control 10 61 18004 P8100-P ±0.002° ±0.01°Z With Peltier temperature control 10 61 18105 T-versions in addition with water specimen temperature control TF-versions in addition with water specimen temperature control and flow function Polarimeter P3000 The polarimeter P3000 is based on the technology of the P8000 series but built for stand- ard applications for which a measurement accuracy of ±0.01° is sufficient and a temper- ature control can be omitted. Typically, the P3000 is used in the quality control of food industry. Like the P8000 models this model performs the record measuring time of approx. 1 second. The P3000 measures up to an optical density of 3.0 OD. Technical data: Scales: Optical rotation [°] Int. sugar scale [°Z] Measurement range: ±90° ±259°Z Measurement accuracy: ±0.01° ±0.01°Z Resolution: 0.01° 0.01°Z Measurement period ±90°: Approx. 1 s Light source: 1 LED with filter Wavelength: 589 nm Temperature measurement: 0 – 99.9°C Optical Investigations Spectroscopy
Made with FlippingBook
RkJQdWJsaXNoZXIy MTIxNDc3OQ==