Catálogo General de Material para Laboratorio

906 pH Electrodes, Buffer Solutions, Accessories w e b c o d e WW5PT012 1 2 3 4 4 5 Electrode Accessories, WINLAB ® Electrode storage bottle The proven solution to the problem of properly storing your pH electrodes. Fill the bottle with 3 moles of KCL solution and insert the electrode through the special seal, so that the electrode is well immersed in the KCL solution. This ensures that the electrode membrane is sealed in an airtight environment surrounded by the correct electrolyte. Article Order No. 1 Electrode storage bottle 250 ml 61 03 80136 incl. screw cap, special seal, 250 ml 3 mol KCL solution Spare KCl solution, 3 mol, 250 ml 61 03 80150 Electrode Storage Rack For the storage of pH electrodes. Being able to be brought in up to 5 pH laboratory elec - trodes into the glass vessels provided for it with special seal of PTFE/silicone in this rack. So pH electrodes are always stored correctly uprightly and in the suitable electrolyte. Article Order No. 2 Electrode storage rack 10 03 80200 Steel wire plastic-coated, 5 storage bottles with screw caps and PTFE/silicone seals, 250 ml 3 mol KCl-solution 3 WinLab ® buffer solutions with test certificate acc. to EN 10204-2.3 Article pH value at 20°C Volume ml Order No. Buffer solution 4.00 500 61 03 04044 Buffer solution 4.00 1000 61 03 04054 Buffer solution 7.00 500 61 03 07044 Buffer solution 7.00 1000 61 03 07054 Buffer solution 9.00 500 61 03 09044 Buffer solution 9.00 1000 61 03 09054 Buffer solution 10.00 500 61 03 10044 Buffer solution 10.00 1000 61 03 10054 4 Technical buffer solutions Coloured buffer solutions for simple and better recognition of the different pH-values. In practical work and storage bottle. With this, you can calibrate directly in the integrated small vessel (s.Foto). Article pH value at 25°C Volume ml Order No. Buffer solution 4.01 1000 10 03 14054 Buffer solution 7.00 1000 10 03 17054 Buffer solution 10.00 1000 10 03 19054 5 Cleaning solutions for pH electrodes Article Order No. For removing protein layers 1) , 250 ml 61 03 98250 For removing protein layers 1) , 500 ml 61 03 98500 Diaphragm cleaner 250 ml 61 03 97250 Spare KCl solution, 3 mol, 250 ml 61 03 80150 1) contains a pepsin/hydrochloric acid mixture w e b c o d e WW37Z003 6 Corrosion Measuring Cell, Meinsberg Thermostable measuring cell for conducting corrosion and general electrochemical tests in the laboratory, consisting of a double-wall cell vessel (max. capacity 500 ml), installation plate, sample holder (working electrode), platinum backplate electrode, current key and intermediate vessel. Corrosion measuring cell Article Order No. 6 KMZ 5 corrosion measuring cell without reference electrode 61 90 70015 Accessories and spare parts Article Order No. KE11NSK7: reference electrode Kalomel 61 90 70003 SE11NSK7: reference electrode Ag/AgCl 61 90 70006 Backplate electrode : platinum plate 4 cm 2 61 90 70001 Haber Lugging capillary for KMZ 3/5; NS 19 10 90 70002 Current key : electrolyte bridge for KMZ 3/5 with single way stopcock NS 7 61 90 70004 Intermediate vessel for electrolyte bridge 61 90 70005 Cell vessel KMZ 5 : glass vessel with built-in plate 61 90 70009 Thermometer : 0 – 100°C, ground joint NS 14.5 61 90 70010 KPG stirrer : Shaft and socket, ground joint NS 29 61 90 70011 Measuring Systems Electrochemistry

RkJQdWJsaXNoZXIy MTIxNDc3OQ==