Catálogo General de Material para Laboratorio

To see other variants and accessories, please enter the webcode on our website. w e b c o d e 903 pH Electrodes, Buffer Solutions, Accessories 9 AT AK Standard redox combination electrodes with glass stem General purpose laboratory use Article Order No. 9 EMC30-L: platinum tip Ø 5 mm; -5 – 80°C 61 90 70300 Liquid electrolyte 3 mol/l KCI (refillable), lab plug head S7-system EMC30-K010-D: as EMC30-L, but with fixed cable + DIN plug 61 90 71300 Redox combination electrode with PSU stem General purpose use, particularly in the water and waste water sector Article Order No. EMC133-L: platinum tip Ø 5 mm; -5 – 80°C 10 90 73133 Gel electrolyte (low-maintenance), lab plug head S7-system EMC133-K010-D: as EMC133-L, but with fixed cable + DIN plug 61 90 71133 Connection cable for pH and redox combination electrodes Connection cable (1 m long; Ø 3 mm) for connecting electrodes with a lab plug head S7-system to the measuring instrument Article Order No. Coax3: S7/S8 connector/DIN connector ; 1 m 61 90 70313 Coax5: S7/S8 connector/BNC connector ; 1 m 61 90 70315 AT Electrolyte and buffer solutions Article Order No. Electrolyte KCL 3 mol/l; 250 ml 61 90 70147 Storage solution and liquid electrolyte for refilling Maintenance set pH, each 250 ml 61 90 70148 Cleaning/Regeneration/KCl solution (3 mol/l) pH buffer solution Tripack NBS, 3 × 250 ml 61 90 70150 acc. to NBS and DIN 19266, pH 4.01; 6.87; 9.18 (25°C) Laboratory buffer solution pH 4,0; 250 ml, red coloured 10 90 70151 Laboratory buffer solution pH 7,0; 250 ml, green coloured 10 90 70152 Laboratory buffer solution pH 9,0; 250 ml, blue coloured 10 90 70153 Laboratory buffer solution pH 10,0; 250 ml 10 90 70154 Redox buffer solution U H = 427 mV; 250 ml 61 90 70427 U H = 427 mV (pH 7), U Pt-Ag/AgCl = 220 mV Redox buffer solution U H = 675 mV; 250 ml 61 90 70675 U H = 675 mV (pH 1), U Pt-Ag/AgCl = 468 mV AK Handheld meters Article Order No. TM40/Set 10 90 74061 pH / mV / ISE / temperature measuring instrument pH 0 – 14; -1999 – 1999 mV; -10 – 100°C; ISE: 0 – 30000 ppm Housing IP 65; integrated data memory; complete measuring kit with pH combination electrode EGA142/TM40 and accessories: 1 × 50 ml storage solution KCl 3 mol/l 3 × 50 ml buffer solution pH 4.01; 6.87 und 9.18 (25°C) LF40/Set 10 90 74062 Conductivity meter; 0 – 20 g/l; 0 – 500 g/l; 2 – 200; 0 – 2000 µS/cm; 0 – 20; 0 – 500 mS/cm; 0 – 100°C; TDS: 0 – 200 mg/l; 0 – 2000 mg/l; 0 – 20 g/l; 0 – 500 g/l; salinity: 0 – 70 g/kg; Housing IP 65; integrated data memory; complete measuring kit with measuring cell LTC0.35/LF40 and accessories: 50 ml calib- ration solution 0.1 N KCl (12.9 mS/cm at 25°C) AM40/Set 10 90 74063 Oxygen meter 0 – 20 mg/l; 0 – 200% saturation; -10 – 100°C Housing IP 65; integrated data memory; complete measuring kit with oxygen sensor MF41N/AM40 and accessories: 2 spare membrane heads, 6 vials of electrolyte Measuring Systems Electrochemistry Failed to find what you are looking for? Give us a call!

RkJQdWJsaXNoZXIy MTIxNDc3OQ==