Catálogo General de Material para Laboratorio

To see other variants and accessories, please enter the webcode on our website. w e b c o d e 715 Table Centrifuges, Universal Centrifuges Rotors only for centrifuges type 5810/5810 R Type Version Speed max. 1/min RCF max. × g Order No. Swing-bucket rotor S-4-104 incl. 4 × 250 ml round beakers 3900 3214 10 69 74000 Swing-bucket rotor S-4-104 incl. 4 × plates beaker (aerosol-tight possible) 3900 2568 10 69 54001 Swing-bucket rotor S-4-104 without suspension ears/beakers 10 69 75508 Swing-bucket rotor A-4-81 incl. 4 × 500 ml rectan- gular beakers 4000 3220 55 69 18007 Swing-bucket rotor A-4-81 incl. 4 × MTP/flex sus- pension gears 4000 2900 55 69 25003 Swing-bucket rotor A-4-81 without suspension gears/beakers 4000 10 69 74301 Swing-bucket rotor A-4-62 incl. 4 × 250 ml rectan- gular beakers 4000 3200 55 69 09008 Swing-bucket rotor A-4-62 incl. 4 × MTP suspensi- on gears 4000 2750 55 69 11002 Deepwell plate rotor A-2-DWP-AT incl. beakers, aerosol- tight caps and plates 4500 3486 10 69 71004 Adapter and accessories for all rotors on request. Accessories for rotor A-4-81 Article Order No. Buckets for 7 x 50 ml Falcon ® test tubes, set of 4 10 69 73003 Adapter for 15 ml Falcon ® test tubes, set of 7 10 69 71805 500 ml wide mouth bottle, set of 2 10 69 70703 Adapters Article Order No. Adapter for 15 ml Falcon ® test tubes, set of 2 10 69 71709 Adapter for 10 ml Oak Ridge tubes, set of 2 10 69 71901 Adapter for 16 ml Oak Ridge tubes, set of 2 10 69 72000 Adapter for 30 ml Oak Ridge tubes, set of 2 10 69 72106 Adapter for 35 ml Oak Ridge tubes, set of 2 10 69 72202 Cell culture centrifuge bundles Whether you need a refrigerated or non-refrigerated centrifuge for low, medium or high-throughput applications, one of these bundles will definitely suit your requirements. The Cell Culture Centrifuge Bundles are optimized for swing-bucket rotor applications in standard 15 ml and 50 ml conical tubes. Cell Culture Centrifuge Bundle includes: • Centrifuge 5804/ 5804 R oder 5810/ 5810 R • Swing-bucket rotor incl. buckets • Four adapters for 15 ml conical tubes (two sets of 2) • Four adapters for 50 ml conical tubes (two sets of 2) Article Order No. Centrifuge 5804, with rotor A-4-44 10 69 58041 incl. adapter for 15 ml/50 ml conical tubes. Max. capacity of conical tubes each rotor: 16 × 15 ml / 4 × 50 ml Centrifuge 5804 R, refrigerated, with rotor A-4-44 10 69 58040 incl. adapter for 15 ml/50 ml conical tubes. Max. capacity of conical tubes each rotor: 16 × 15 ml / 4 × 50 ml Centrifuge 5804, with rotor S-4-72 10 69 58042 incl. adapter for 15 ml/50 ml conical tubes. Max. capacity of conical tubes each rotor: 32 × 15 ml / 16 × 50 ml Centrifuge 5804 R, refrigerated, with rotor S-4-72 10 69 58043 incl. adapter for 15 ml/50 ml conical tubes. Max. capacity of conical tubes each rotor: 32 × 15 ml / 16 × 50 ml Centrifuge 5810, with rotor A-4-62 10 69 58100 incl. adapter for 15 ml/50 ml conical tubes. Max. capacity of conical tubes each rotor: 36 × 15 ml / 16 × 50 ml Centrifuge 5810 R, refrigerated, with rotor A-4-62 10 69 58102 incl. adapter for 15 ml/50 ml conical tubes. Max. capacity of conical tubes each rotor: 36 × 15 ml / 16 × 50 ml Centrifuge 5810, with rotor A-4-81 10 69 58101 incl. adapter for 15 ml/50 ml conical tubes. Max. capacity of conical tubes each rotor: 48 × 15 ml / 20 × 50 ml Centrifuge 5810 R, refrigerated, with rotor A-4-81 10 69 58103 incl. adapter for 15 ml/50 ml conical tubes. Max. capacity of conical tubes each rotor: 48 × 15 ml / 20 × 50 ml Centrifuge 5810, with rotor S-4-104 10 69 58104 incl. adapter for 15 ml/50 ml conical tubes. Max. capacity of conical tubes each rotor: 56 × 15 ml / 28 × 50 ml Centrifuge 5810 R, refrigerated, with rotor S-4-104 10 69 58105 incl. adapter for 15 ml/50 ml conical tubes. Max. capacity of conical tubes each rotor: 56 × 15 ml / 28 × 50 ml Separating Systems Centrifugation

RkJQdWJsaXNoZXIy MTIxNDc3OQ==