Catálogo General de Material para Laboratorio
Continued on next page To see other variants and accessories, please enter the webcode on our website. w e b c o d e 537 Series FD: Drying chambers with forced convection Model Interior vol. l Outer W × H × D mm Inner W × H × D mm Order No. FD 56 60 560×625×565 400×440×345 10 40 10303 FD 115 116 710×735×605 550×550×385 10 40 10305 FD 260 259 810×965×760 650×780×515 10 40 10309 FD 720 741 1165×1590×870 1000×1300×570 10 40 10311 Safety Drying Ovens Series FED: Heating chambers with forced convection and enhanced timer functions Model Interior vol. l Outer W × H × D mm Inner W × H × D mm Order No. FED 56 60 560×625×565 400×440×345 10 40 10295 FED 115 116 710×735×605 550×550×385 10 40 10293 FED 260 259 810×965×760 650×780×515 10 40 10299 FED 720 741 1165×1590×870 1000×300×570 10 40 10301 You will find further model sizes in the Classic.Line Incubators, Cooled Incubators w e b c o d e WWW4U037 Drying Ovens, LAT Bench-top unit for incubating smeared or dipped slides or conventional petri dishes, incl. insert rack. • 25°C to 45°C • ±1°C • 220 V / 110 V / 12 V • 26 W • Protection class II • Thermometer in the unit • Plexiglas front panel • External W×H×D: 310 × 155 × 168 mm • Internal W×H×D: 220 × 120 × 150 mm Article Order No. Drying oven LATURA 41 80 50000 w e b c o d e WW91A002 Incubators, Memmert Incubators for research, medicine, pharmaceutics, and food technology. Organic materi- al requires particularly gentle heating. For this reason, heating and control of these incu- bators have been optimised specifically for low temperatures of up to +80°C. To avoid overshoots, the temperature is increased within a very narrow range and maintained ac- curately at the setpoint value. • With large area all-round heating • Pre-heating of the fresh air • With interior glass door Medical product certification: Memmert Im incubators are class I. Until the entry into force of Regulation (EU) 2017/745 (MDR), Memmert Class I medical devices will be placed on the market in accordance with EU Directive 93/42 / EEC. After the regulation comes into force, Memmert will market Class I medical devices in accordance with MDR. In accordance with their intended use, Memmert Im incubators may be used for controlling the temperature of flushing and infu- sion solutions and contrast agents. All of the product information below also applies to the medical devices Im. IN and IF incubators N = Natural convection F = Forced air circulation 2 model variants: SingleDISPLAY and TwinDISPLAY (a detailed description of the two variants can be found on page 531) Technical data: Work temperature range: at least 5°C (UN), at least 10°C (UF) bove room temperature up to +80°C Set temperature range: +20°C up to +80°C Setting accuracy: 0.1°C Electrical supply: 230 V 50/60 Hz (other voltages to special order) Heating Units, Refrigerating Units Temperature Controllers
Made with FlippingBook
RkJQdWJsaXNoZXIy MTIxNDc3OQ==